LED panels are recessed into suspended ceilings in offices, schools, hospitals, shops and meeting rooms and give soft, even light from a large surface. Plana and Sottile come in 30×30, 30×60, 60×60 and 30×120 cm for mineral-fibre (lay-in) and clip-in ceilings; Cornice has a decorative frame, and Pura is an IP65 sealed model for hospitals and clean rooms.

How many do I need? Calculate in 3D →

Products

LED Panels: model comparison

Values are taken from the product datasheets; ranges show the lowest and highest variant. Click a model name for details.

ModelPowerLuminous fluxEfficacyColour temp.CRIIPSizeProduct code
Plana LED Panel14–36 W1.680–4.320 lm120 lm/W4000 K / 6500 KRa > 80IP40595 × 595 × 65 mm20 01 PN SA 001
Sottile LED Panel14–36 W1.540–3.960 lm105–110 lm/W4000 K / 6500 KRa > 80IP40595 × 595 × 35 mm20 01 PN SA 002
Cornice Decorative LED Panel14–36 W1.680–4.320 lm120 lm/W4000 K / 6500 KRa > 80IP40595 × 595 × 65 mm20 01 PN SA 003
Pura Clean-Room LED Panel24–36 W2.880–4.140 lm115–120 lm/W4000 K / 6500 KRa > 80IP65595 × 595 × 90 mm20 01 PN SA 004

What is an LED panel and which model suits which space?

An LED panel is a square or rectangular luminaire recessed into a suspended ceiling that gives soft, even light from a large surface. It provides general lighting in offices, schools, hospitals, shops and meeting rooms. Plana, Sottile and Cornice are IP40; Pura is an IP65 sealed model for hospitals, laboratories and clean rooms.

ModelConstructionEfficacyProtectionUse
Plana65 mm high, steel frame, opal diffuser120 lm/WIP40Offices, schools, hospitals, shops
Sottile35 mm high, backlit105–110 lm/WIP40Offices, schools, hospitals, shops
Cornice65 mm high, decorative frame120 lm/WIP40Offices, schools, hospitals, shops
Pura90 mm high, 5 mm tempered glass front115–120 lm/WIP65Hospitals, laboratories, clean rooms

LED panel sizes, power and luminous flux

Nominal sizePowerPlana, CorniceSottilePura
30×30 cm14 W1,680 lm1,540 lm–
30×60 cm24 W2,880 lm2,640 lm2,880 lm
60×60 cm36 W4,320 lm3,960 lm4,140 lm
30×120 cm36 W4,320 lm3,960 lm4,140 lm

The panels have a colour rendering of Ra>80 and a colour temperature of 4000K or 6500K. DALI and 1-10V control and an emergency lighting kit are available. All products carry a 3-year warranty.

LED panel sizes by ceiling type

Nominal sizeRecessed (mineral fibre)Clip-inSurface-mounted
30×30 cm295×295 mm299×299 mm300×300 mm
30×60 cm295×595 mm299×599 mm300×600 mm
60×60 cm595×595 mm599×599 mm600×600 mm
30×120 cm295×1195 mm299×1199 mm300×1200 mm

These sizes apply to Plana, Sottile and Cornice. Pura is recessed only, with an additional 597×597 mm surface-mounted option at 60×60 cm. Check your ceiling system before ordering.

How many LED panels does a room need?

A first estimate uses the lumen method: required total luminous flux = target illuminance × area ÷ (utilisation factor × maintenance factor).

Example: for a 6 × 5 m (30 m²) office with a 500 lux target, assuming a utilisation factor of 0.6 and a maintenance factor of 0.8, the required flux is 500 × 30 ÷ (0.6 × 0.8) ≈ 31,250 lm. With a 4,320 lm 60×60 cm Plana, 31,250 ÷ 4,320 ≈ 7.2, so about 8 panels. This is a rough first estimate; the real result depends on room proportions, surface colours and layout. For your own room, use the 3D Light Planner.

What to check in offices, schools and hospitals

  • Offices: The target at the desk is 500 lux and UGR ≤ 19. Our panel data states UGR<20, so if the target is UGR ≤ 19 the layout should be checked at the design stage. See office lux levels.
  • Schools: For classroom targets and board lighting, see our school and classroom lighting guide.
  • Hospitals: For values by area, see our hospital lighting guide. Where clean areas need protection from dust and moisture, consider the IP65 Pura.

For a quote, send us the plan, ceiling type and control system you want.

Related guides

  • Hospital and Clinic Lighting: Values by Area

    Under EN 12464-1 the typical targets in patient rooms are 100 lx for general lighting and 300 lx for reading, 1000 lx for examination and treatment, and 100–200 lx in corridors by day with a lower level at night. CRI 90 in examination areas, cleanable luminaires protected against dust (IP54 and above), night lights, emergency lighting and dimmable control are recommended. Surgical lights are covered by a separate standard.

  • Lux Levels in Office Lighting: A Guide Based on EN 12464-1

    According to EN 12464-1, an average of 500 lux, a glare limit of UGR ≤ 19, uniformity of 0.60 and at least CRI 80 are targeted at office desks used for writing, reading and screen work. 500 lux is also enough in meeting rooms and 100 lux in corridors. Low-glare luminaires and a 4000K colour temperature are common choices in offices with screens.

  • School and Classroom Lighting: EN 12464-1 Values and Advice

    Under EN 12464-1 the typical target is 300 lx in classrooms (500 lx for evening use and adult education), 500 lx on the board, 500–750 lx in technical drawing rooms and laboratories, and 100 lx in corridors. Glare below UGR 19, CRI of at least 80, flicker-free drivers and control that dims the window side according to daylight are recommended.

Frequently Asked Questions

Which ceilings do LED panels fit?

They sit in mineral-fibre (60×60 grid) suspended ceilings, and clip-in versions fit metal clip-in ceilings. Where there is no suspended ceiling, a surface-mounting frame can be used.

How many watts should a 60×60 LED panel be?

36 W is common for 60×60 panels in offices; the right wattage and quantity are calculated from the target illuminance (e.g. 500 lux at the desk) and ceiling height.

Which panel should be chosen for hospitals?

Laboratories and clean rooms call for IP65 sealed panels with a glass front that keep out dust and moisture. Requirements for special areas such as operating theatres are set by the project specification.

How many lumens does a 60×60 LED panel have?

In our range a 36 W 60×60 cm panel gives 4,320 lm in Plana and Cornice, 3,960 lm in Sottile and 4,140 lm in Pura (4,248 lm in the surface-mounted Pura option).

What is the difference between mineral-fibre and clip-in LED panels?

The difference is the ceiling system. A mineral-fibre (recessed) panel measures 595×595 mm and a clip-in panel 599×599 mm. The wrong size will not sit in the ceiling, so confirm the ceiling type before ordering.

What affects the price of an LED panel?