Frequently Asked Questions

244 questions and short answers about LED lighting, choosing luminaires and lighting design.

Lighting design and consultancy

What is a lighting design?

A lighting design is a technical study that shows, through calculations and drawings, which luminaires are installed where, in what quantity and wattage, and what illuminance, uniformity and glare each area will achieve with that layout.

Details: Lighting design and consultancy

When is lighting consultancy needed?

It is recommended for new buildings and refurbishments, LED retrofits of existing lighting, when energy consumption needs to be reduced, when users complain about eye strain or glare, and when compliance with standards has to be documented.

Details: Lighting design and consultancy

What information is needed for a lighting design?

Architectural drawings (preferably DWG or PDF), ceiling height and type, the use of each area, interior colours and materials if available, and the desired colour temperature and controls. Without drawings we can start from dimensions.

Details: Lighting design and consultancy

Which standard are the calculations based on?

EN 12464-1 for indoor workplaces, EN 1838 for emergency lighting and EN 13201 for road lighting. The target illuminance, uniformity and glare for each area are taken from these standards.

Details: Lighting design and consultancy

What is delivered at the end of the project?

An illuminance calculation report per area, the luminaire layout on the architectural plan, a luminaire schedule with technical data, and an installed power and energy consumption summary.

Details: Lighting design and consultancy

What is the difference between a lighting specification and a lighting design?

A lighting design shows on a plan which luminaire goes where and in what quantity, backed by a calculation. A specification states which technical requirements the luminaires must meet. The design sets quantity and layout; the specification sets quality.

Details: How to Write a Lighting Specification: Luminaire Clauses and Equivalence Criteria

Should a brand be named in the specification?

It can be, but a brand name alone is not enough. If a brand is named, add "or equivalent" and state how equivalence will be measured: luminous flux, wattage, optics, UGR, Ra, colour temperature, IP and control protocol.

Details: How to Write a Lighting Specification: Luminaire Clauses and Equivalence Criteria

How is an equivalent luminaire evaluated?

First compare the numerical values in the specification. Then repeat the illuminance calculation with the proposed luminaire's LDT or IES file; if the target illuminance, uniformity and UGR are met, check dimensions, mounting and control compatibility.

Details: How to Write a Lighting Specification: Luminaire Clauses and Equivalence Criteria

Which documents should a specification request?

Luminaire datasheet, LDT or IES file, CE declaration of conformity, warranty document, test reports for luminous flux and lifetime (for example IES LM-79, LM-80 and TM-21) and the relevant conformity documents if emergency lighting is included.

Details: How to Write a Lighting Specification: Luminaire Clauses and Equivalence Criteria

Is 500 lux enough under EN 12464-1?

For writing, reading and data processing in offices the required maintained value is 500 lux. The 2021 edition defines context modifiers that raise this value where visual work is critical or long; if they apply, a higher value should be specified.

Details: How to Write a Lighting Specification: Luminaire Clauses and Equivalence Criteria

What is the difference between a takeoff and a bill of quantities?

A takeoff is the work of measuring quantities from the drawings. A priced bill of quantities adds a unit price column to the takeoff summary and gives the approximate cost of the work.

Details: How to Do a Lighting Takeoff: Luminaires, Track, Drivers and Controls

Which documents is a lighting takeoff based on?

The architectural plan, ceiling plan, room schedule, electrical drawings and, where available, the lighting calculation and specification.

Details: How to Do a Lighting Takeoff: Luminaires, Track, Drivers and Controls

What is counted in a track system takeoff?

Total track length plus power feeds, end caps, connectors, L, T or X corners, adapters, suspension parts and the number of spotlights on the track, each as a separate item.

Details: How to Do a Lighting Takeoff: Luminaires, Track, Drivers and Controls

How is the number of DALI lines calculated?

One DALI line supports 64 addresses. Divide the total number of luminaires by 64 and round up. For example, 140 luminaires need at least 3 lines; leaving a margin for later additions is recommended.

Details: How to Do a Lighting Takeoff: Luminaires, Track, Drivers and Controls

How is the luminaire quantity set before the takeoff?

The lumen method is used for early sizing: number of luminaires = (target lux × area) ÷ (luminaire lumens × utilisation factor × maintenance factor). The final quantity is verified with lighting calculation software.

Details: How to Do a Lighting Takeoff: Luminaires, Track, Drivers and Controls

What is the difference between IES and LDT files?

Both carry the same kind of photometric data. IES (LM-63) is the North American format; LDT (EULUMDAT) is common in Europe. DIALux and Relux read both.

Details: What Are IES and LDT Files? Using Them in DIALux and Relux

How do I open an IES file?

The file is imported into DIALux or Relux as a luminaire; free photometric file viewers can also show the light distribution curve. Opened in a text editor, the header information (manufacturer, model, lumens) can be read.

Details: What Are IES and LDT Files? Using Them in DIALux and Relux

Is a separate IES file needed for every colour temperature and optic?

When the beam angle (optic) changes, the distribution curve changes, so each optic needs its own file. When colour temperature and CRI change, the distribution stays the same but the luminous flux may change; the correct lumen value must be used in the calculation.

Details: What Are IES and LDT Files? Using Them in DIALux and Relux

Where can I get IES files for Harmony ELS luminaires?

You can request the IES files of the products you want to use through the contact form or by e-mail; files are shared per product and optic.

Details: What Are IES and LDT Files? Using Them in DIALux and Relux

How is the number of luminaires calculated for factory lighting?

With the lumen method: number of luminaires = (target lux × area) ÷ (luminaire lumens × utilisation factor × maintenance factor). The result is rounded to a regular grid and verified with software.

Details: Factory Lighting Calculation: Number of Luminaires and Power with a Worked Example

What is the room index?

It expresses the geometry of the space in one number: k = (length × width) ÷ (mounting height × (length + width)). The utilisation factor is read from the luminaire's photometric table according to this value and the surface reflectances.

Details: Factory Lighting Calculation: Number of Luminaires and Power with a Worked Example

What maintenance factor should be used in a dusty factory?

About 0.8 is usually used in clean environments; in dusty and dirty environments lower values are used, depending on how often the luminaires are cleaned.

Details: Factory Lighting Calculation: Number of Luminaires and Power with a Worked Example

How much power is saved by converting metal halide luminaires to LED?

For the same illuminance the installed power usually falls clearly; in the hall of the worked example, installed power drops to about one third compared with the 400 W metal halide solution.

Details: Factory Lighting Calculation: Number of Luminaires and Power with a Worked Example

Which documents are needed for a lighting design?

The architectural plan (DWG or PDF), ceiling height and type, the use of each area, surface colours and materials.

Details: How Is a Lighting Design Prepared? Step-by-Step Calculation and Layout

What is the lumen method?

A preliminary sizing method that calculates the total luminous flux needed to achieve the target illuminance in an area: number of luminaires = (target lux × area) ÷ (luminaire lumens × utilisation factor × maintenance factor).

Details: How Is a Lighting Design Prepared? Step-by-Step Calculation and Layout

Why is the lighting calculation verified with software?

The lumen method gives an average value. Software uses the luminaire's real light distribution (photometric file) to calculate the illuminance, uniformity and glare at every point, showing corners that stay dark or spots that cause glare.

Details: How Is a Lighting Design Prepared? Step-by-Step Calculation and Layout

What is the maintenance factor?

A coefficient that takes into account that illuminance will fall as the luminaire gets dirty and the LED loses light over time. It is usually about 0.8 in clean interiors and lower in dusty environments.

Details: How Is a Lighting Design Prepared? Step-by-Step Calculation and Layout

Choosing LED luminaires

What is the difference between a downlight and a spotlight?

A downlight lights an area generally with a wide beam (60°–120°); a spotlight highlights a specific point with a narrow beam (10°–40°) and is adjustable on most models. The two are usually used together in a space.

Details: What Is a Downlight? How It Differs from a Recessed Spotlight

Should I choose a reflector or an opal diffuser downlight?

A reflector downlight controls light more tightly and causes less glare; it suits offices and shops. An opal diffuser downlight spreads light softly and evenly; it is preferred in homes, corridors and waiting areas.

Details: What Is a Downlight? How It Differs from a Recessed Spotlight

How far apart should downlights be placed?

For wide-beam downlights the spacing is roughly equal to the ceiling height (2.5–3 m for a 2.8 m ceiling). The exact spacing is set by a DIALux or Relux calculation for the target illuminance.

Details: What Is a Downlight? How It Differs from a Recessed Spotlight

Which downlight should be used in a bathroom?

In wet rooms use downlights rated at least IP44; directly above the shower a higher rating is preferred.

Details: What Is a Downlight? How It Differs from a Recessed Spotlight

What is acoustic lighting?

A lighting solution in which an LED luminaire is combined with a sound-absorbing surface, usually recycled PET felt. The luminaire provides light while the felt reduces reflections of speech and noise.

Details: What Is Acoustic Lighting? Luminaires That Reduce Echo

What does the NRC value tell you?

NRC (Noise Reduction Coefficient) shows, on a scale from 0 to 1, how much sound a material absorbs on average at speech frequencies. NRC 0.70 means that on average 70 per cent of the sound hitting the surface is absorbed.

Details: What Is Acoustic Lighting? Luminaires That Reduce Echo

Can an acoustic luminaire replace acoustic panels?

Not always on its own. How much the echo is reduced depends on the total sound-absorbing area in the room. Acoustic luminaires provide part of the required absorption on the ceiling, together with the lighting; large and very hard spaces are planned with wall or ceiling panels as well.

Details: What Is Acoustic Lighting? Luminaires That Reduce Echo

Are felt luminaires safe in terms of fire?

Check the fire class of the felt. Class B-s1,d0 under EN 13501-1 means the material is hard to ignite, produces little smoke and does not drip when burning; the US equivalent is ASTM E84 Class A.

Details: What Is Acoustic Lighting? Luminaires That Reduce Echo

What is rope lighting?

A lighting system in which luminaires are clipped onto a flexible rope carrying 48 V DC conductors. The rope acts as both carrier and power line; luminaires slide to any point along it and are fixed there.

Details: What Is Rope Lighting? System, Components and Installation

What is the difference between rope lighting and magnetic track?

Both run on 48 V low voltage. Magnetic track is a straight aluminium profile recessed into or fixed to the ceiling; rope is flexible, so it can hang, be stretched crosswise and form free lines from ceiling to wall.

Details: What Is Rope Lighting? System, Components and Installation

How many luminaires can be used with rope lighting?

The driver rating sets the limit. The total power of the luminaires on a 150 W, 48 V DC driver must not exceed 150 W; for example, up to 10 luminaires of 15 W or 25 small globes of 6 W. Longer runs get a second driver.

Details: What Is Rope Lighting? System, Components and Installation

Can rope lighting be used in a bathroom or outdoors?

No. The system is rated IP20 and is used only in dry indoor spaces, away from water and high humidity.

Details: What Is Rope Lighting? System, Components and Installation

Which documents should be requested from a manufacturer?

For each product: a datasheet, an LM-79 report showing system lumens, LM-80/TM-21 data for LED lifetime, EN 60598 safety and EN 55015 EMC test reports, and a CE declaration of conformity.

Details: How to Choose an LED Luminaire Manufacturer? A Supplier Evaluation Checklist

What is the advantage of locally manufactured luminaires?

Project-specific adaptation of wattage, size, colour and optics is faster; spare parts and drivers are easy to obtain, and production can be seen on site with a factory visit.

Details: How to Choose an LED Luminaire Manufacturer? A Supplier Evaluation Checklist

How long should the warranty on an LED luminaire be?

Five years is a common expectation in commercial projects; ask in writing under which operating conditions (temperature, operating hours) the warranty applies.

Details: How to Choose an LED Luminaire Manufacturer? A Supplier Evaluation Checklist

Should the manufacturer carry out lighting calculations?

It is a great advantage in projects; at the very least the manufacturer should be able to supply photometric files (IES/LDT) for its products so that calculations can be made.

Details: How to Choose an LED Luminaire Manufacturer? A Supplier Evaluation Checklist

What lm/W value should a good LED luminaire have?

Quality industrial LED luminaires reach 130–160 lm/W and premium office luminaires 120–140 lm/W. 80–100 lm/W is budget-product level. The value is calculated by dividing the system lumens in the luminaire's LM-79 report by its total power.

Details: How to Choose an LED Luminaire? A Complete Guide from a Purchasing and Quality Expert

What is the minimum power factor (PF) for an LED luminaire?

At least 0.90 in commercial and industrial projects. In sensitive applications such as offices, hotels and hospitals 0.95 is targeted, and 0.98 or higher in large facilities.

Details: How to Choose an LED Luminaire? A Complete Guide from a Purchasing and Quality Expert

What does L70B50 mean?

L70 is the time after which the luminaire's light output falls to 70% of its initial value; B50 means that half of the luminaires of the same model have reached this point. A claim of "L70B50 @ 50,000 hours" is only meaningful when supported by LM-80 measurements and a TM-21 calculation.

Details: How to Choose an LED Luminaire? A Complete Guide from a Purchasing and Quality Expert

Does the CE mark show that a luminaire is of good quality?

No. CE is a declaration of conformity signed by the manufacturer itself. For real assurance, EN 60598 (luminaire safety) and EN 55015 (EMC) test reports should be requested, and marks from independent bodies such as ENEC, VDE or TÜV should be verified with the certificate number.

Details: How to Choose an LED Luminaire? A Complete Guide from a Purchasing and Quality Expert

What does an LED lifetime of 50,000 hours mean?

LEDs do not fail suddenly; they lose light over time. 50,000 hours usually refers to the time after which light output falls to 70% of its initial value (L70). For a luminaire running 10 hours a day, this is about 13.7 years.

Details: What Is an LED and How Does It Work? Understanding the Future of Light

Why do LEDs get hot, and how does heat affect lifetime?

The LED chip converts part of its energy into heat, which builds up at the junction of the chip. As the temperature rises, light output falls and lifetime shortens; that is why quality luminaires use aluminium heat sinks to keep the junction temperature below 85°C.

Details: What Is an LED and How Does It Work? Understanding the Future of Light

What does an LED driver do?

It converts the alternating current of the mains into the constant direct current the LED needs, keeps the brightness stable and protects the chip from overcurrent. The lifetime of a luminaire often depends on the quality of the driver before that of the LED.

Details: What Is an LED and How Does It Work? Understanding the Future of Light

Technical terms: CRI, IP, watt, colour temperature

What does L80B10 mean?

At the end of the stated period (for example 50,000 hours) at most 10% of luminaires fall below 80% of their initial luminous flux; the other 90% stay above 80%.

Details: How to Read LED Lifetime: L70, L80, B10, B50 and TM-21

Which is better, L70B50 or L80B10?

For the same period L80B10 is the stricter claim: it allows less light loss (20%) and fewer luminaires (10%). L70B50 accepts 30% loss and half of the luminaires.

Details: How to Read LED Lifetime: L70, L80, B10, B50 and TM-21

What is TM-21?

A method that projects lifetime from the LED lumen loss data measured in the LM-80 test. The projection may be reported up to 6 times the test duration; a 10,000-hour test supports a claim of at most about 60,000 hours.

Details: How to Read LED Lifetime: L70, L80, B10, B50 and TM-21

Does LED lifetime include driver lifetime?

No. The Lx By value describes the LED's light loss; driver, capacitor and connection failures are assessed separately. The real life of a luminaire often depends on driver quality and operating temperature.

Details: How to Read LED Lifetime: L70, L80, B10, B50 and TM-21

How many years is a 50,000-hour LED lifetime?

About 24 years at 8 hours a day, 5 days a week; about 11.4 years at 12 hours every day; and about 5.7 years in continuous operation. The calculation covers only the LED's light loss; the driver is assessed separately.

Details: How to Read LED Lifetime: L70, L80, B10, B50 and TM-21

Is the difference between CRI 80 and CRI 90 visible?

In general office use the difference is limited. Where colours matter, such as skin tones, food, textiles and artworks, CRI 90+ light shows colours clearly more vivid and natural.

Details: What Is CRI? The Parameter That Reveals the True Colours of Objects

What is the R9 value and why should it be asked for separately?

R9 measures how accurately the saturated red test colour is shown and is not included in the standard CRI average. So two luminaires with CRI 90 can have very different R9 values; in projects where meat, wood and skin tones matter, "CRI > 90, R9 > 50" should be specified together.

Details: What Is CRI? The Parameter That Reveals the True Colours of Objects

Are CRI and colour temperature the same thing?

No. Colour temperature (Kelvin) describes whether light looks warm or cool; CRI describes how accurately it shows colours. A 2700K light can have CRI 95, and a 6500K light can have CRI 70.

Details: What Is CRI? The Parameter That Reveals the True Colours of Objects

How is CRI measured?

The spectral power distribution of the light source is measured with a spectrometer, and the appearance of test colours R1–R8 is compared with their appearance under a reference light. Extended measurements also include colours R9–R15.

Details: What Is CRI? The Parameter That Reveals the True Colours of Objects

How many watts of LED replace a 60 W incandescent bulb?

A 60 W incandescent bulb gives about 800 lumens. With an LED of 100 lm/W efficacy, the same light is obtained at about 8 W; depending on the product's efficacy, the value varies between 7 and 10 W.

Details: What Is a Watt and How Is It Calculated? Power and Efficacy in LED Lighting

How is the monthly electricity consumption of lighting calculated?

Consumption (kWh) = total power (kW) × operating time (hours). For example, if 50 luminaires of 20 W (1 kW) run for 10 hours a day on 22 days a month, monthly consumption is 220 kWh.

Details: What Is a Watt and How Is It Calculated? Power and Efficacy in LED Lighting

Does an LED get brighter as the wattage increases?

Usually yes within the same product family. When comparing different products, however, the deciding factors are lumens and lm/W, not watts; an efficient low-wattage luminaire can be brighter than an inefficient high-wattage one.

Details: What Is a Watt and How Is It Calculated? Power and Efficacy in LED Lighting

What Kelvin value should be chosen for a bedroom?

Warm white light of 2700K–3000K and, if possible, a dimmer are recommended. Warm tones do not suppress melatonin production and make it easier to fall asleep; cool white light should be avoided in the hours before bed.

Details: Warm Light or White Light? The Science of Choosing a Colour Temperature

Which light colour should be used in an office?

Neutral to cool white light of 4000K–5000K suits tasks that need attention; it supports concentration and shows colours clearly.

Details: Warm Light or White Light? The Science of Choosing a Colour Temperature

Is 4000K warm light or white light?

4000K is neutral white. It is neither as warm as yellowish light nor as cool as 6500K daylight, which is why it is often chosen for kitchens, bathrooms and multi-purpose spaces.

Details: Warm Light or White Light? The Science of Choosing a Colour Temperature

What is tunable white?

A technology that lets one luminaire emit light at different colour temperatures, usually between 2700K and 6500K. It is the basis of human-centric lighting, which changes the light during the day in line with the natural daylight cycle.

Details: Warm Light or White Light? The Science of Choosing a Colour Temperature

Which colour temperature should a shop use?

It depends on the product: 2700K–3000K with CRI 90+ in clothing stores, 4000K–5000K in electronics stores, and in jewellery 2700K–3000K for gold and 4000K–5000K for diamonds and platinum.

Details: The Importance of Colour Temperature in Lighting Design

Can different Kelvin values be used in the same space?

They can, but a difference of more than 500K within the same visual scene causes eye strain. Transitions between different zones such as lobbies and corridors should be designed gradually.

Details: The Importance of Colour Temperature in Lighting Design

Does colour temperature make a space look bigger or smaller?

Yes. Cool tones create contrast and clarity and make a space feel larger; warm tones create an intimate, smaller-feeling atmosphere.

Details: The Importance of Colour Temperature in Lighting Design

What is the difference between IP65 and IP67?

Both are completely dust-tight. IP65 withstands low-pressure water jets; IP67 withstands immersion at a depth of 1 metre for 30 minutes. IP67 should be chosen for ground and recessed applications where water can collect.

Details: What Is an IP Rating? A Technical Guide to Choosing Outdoor Luminaires

What IP rating is needed for a bathroom luminaire?

At least IP44 should be used in bathrooms. Higher protection should be chosen close to the shower and bath, where water splashes directly.

Details: What Is an IP Rating? A Technical Guide to Choosing Outdoor Luminaires

What is the difference between the IP and IK ratings?

IP shows protection against dust and water; IK (IEC 62262) shows resistance to mechanical impact. IK10 means resistance to an impact of 20 joules; in schools, sports halls and public areas both values should be checked together.

Details: What Is an IP Rating? A Technical Guide to Choosing Outdoor Luminaires

How is an IP rating verified?

Dust and water tests are carried out to IEC 60529 in an accredited laboratory. Look at the test report rather than the manufacturer's declaration and, if possible, at approval from an independent body such as VDE or TÜV.

Details: What Is an IP Rating? A Technical Guide to Choosing Outdoor Luminaires

Indoor lighting

What is an equivalent luminaire?

It is a product proposed in place of the luminaire named in a specification or bill of quantities that delivers the required light result and meets the electrical, control and mounting requirements under the same conditions. It does not have to be a copy of the reference product; it has to meet the specified values and reach the targets in the calculation.

Details: Equivalent Luminaires: Technical Comparison, Calculation and Approval Steps

How do you compare an equivalent luminaire?

Compare luminaire luminous flux, system power, light distribution, UGR, colour temperature, Ra, lifetime, control protocol, IP rating and dimensions. Then repeat the illuminance calculation with the proposed luminaire's LDT or IES file, using the parameters of the original design.

Details: Equivalent Luminaires: Technical Comparison, Calculation and Approval Steps

Is the luminaire with more lumens the better equivalent?

Not always. If the light distribution differs, a luminaire with more lumens can deliver less illuminance on the working plane or increase glare. The calculation with the proposed luminaire's photometric file decides the result.

Details: Equivalent Luminaires: Technical Comparison, Calculation and Approval Steps

Is a DIALux calculation required for an equivalent?

Yes, if the illuminance target must be documented. The calculation is repeated in software such as DIALux or Relux, with the proposed luminaire's LDT or IES file and the reflectance, maintenance factor, working plane and layout values of the original calculation.

Details: Equivalent Luminaires: Technical Comparison, Calculation and Approval Steps

Can a brand be named in a Turkish public tender specification?

Under Article 12 of Public Procurement Law No. 4734, technical specifications cannot be written around a particular brand or model. Where no national or international standard exists, or the technical characteristics cannot be defined, a brand or model may be named with the words "or equivalent". The tender documents and current legislation apply.

Details: Equivalent Luminaires: Technical Comparison, Calculation and Approval Steps

What kind of light should a car showroom use?

To show the lines of the bodywork and the gloss of the paint, general lighting is high and even, and cars are highlighted with adjustable spotlights. The number of point sources reflected in glossy paint is limited; 4000K and CRI 90 are preferred.

Details: Showroom Lighting: Car, Furniture and Ceramics Showrooms

Which colour temperature suits a furniture showroom?

Warm white of 2700K–3000K, which evokes a home, is preferred. CRI 90 or higher is recommended so that wood and fabric colours look true.

Details: Showroom Lighting: Car, Furniture and Ceramics Showrooms

How can reflections be avoided in a ceramics and sanitaryware showroom?

The image of the luminaire reflects in glossy surfaces. Light is aimed at the surface at about 30°, and deep-reflector, low-glare luminaires are chosen; 4000K suits neutral colours.

Details: Showroom Lighting: Car, Furniture and Ceramics Showrooms

How many lux should museum objects be lit with?

Widely accepted limits: about 50 lx for highly sensitive works such as paper, textiles, watercolours and photographs; about 150–200 lx for moderately sensitive works such as oil paintings, wood and leather; no light limit for insensitive objects such as stone, metal and ceramics. The total annual light dose is also limited.

Details: Museum and Gallery Lighting: Showing the Work While Protecting It

Why is LED preferred for museum lighting?

LED emits almost no UV and no heat in the direction of the light, can be dimmed and puts light only on the work with narrow-beam optics. This reduces fading and heat damage.

Details: Museum and Gallery Lighting: Showing the Work While Protecting It

Which colour temperature and CRI should a gallery use?

Most exhibitions use 3000K; 4000K may also be preferred for modern art and photography. For colour accuracy, CRI 95 or higher with a high R9 value is recommended.

Details: Museum and Gallery Lighting: Showing the Work While Protecting It

How can reflections on glass cases be avoided?

The spotlight is aimed at the case from outside the visitor's line of sight at about 30°; when lighting inside the case is used, the light source is concealed.

Details: Museum and Gallery Lighting: Showing the Work While Protecting It

How many lux should a classroom have?

Under EN 12464-1 the typical target for primary and secondary classrooms is 300 lx; 500 lx is recommended for classrooms used in the evening and for adult education. The board is lit separately with 500 lx.

Details: School and Classroom Lighting: EN 12464-1 Values and Advice

How is a whiteboard lit?

A luminaire with an asymmetric optic is placed in the ceiling in front of the board; light falls evenly on the board without dazzling the teacher or pupils and without reflecting on the board.

Details: School and Classroom Lighting: EN 12464-1 Values and Advice

What should be checked in LED luminaires for schools?

Low glare (UGR < 19), a flicker-free driver, at least Ra 80, an impact-resistant housing and, in sports halls, protection against ball impact.

Details: School and Classroom Lighting: EN 12464-1 Values and Advice

How many lux should a patient room have?

Under EN 12464-1 the typical target is 100 lx for general lighting, 300 lx for reading in bed and 300 lx for simple examination. At night a very low night light is used that does not wake the patient.

Details: Hospital and Clinic Lighting: Values by Area

What kind of light does an examination room need?

About 1000 lx in the examination and treatment area, and CRI 90 or higher so that changes in skin colour can be seen.

Details: Hospital and Clinic Lighting: Values by Area

Why does IP matter for hospital luminaires?

Because of frequent cleaning and disinfectants, luminaires protected against dust and water (IP54 or higher) with flat, easy-to-wipe surfaces are preferred; sensitive areas require higher protection.

Details: Hospital and Clinic Lighting: Values by Area

Is operating theatre lighting designed to the same values?

General lighting in the operating theatre is planned under EN 12464-1; surgical lights that illuminate the operating field are medical devices covered by a separate standard (IEC 60601-2-41).

Details: Hospital and Clinic Lighting: Values by Area

Which colour temperature should be used for gold?

Gold looks richer and more yellow under warm white light of 2700K–3000K. White gold, diamonds and silver look brighter and cleaner under neutral or cool white of 4000K–5000K.

Details: Jewellery and Display Lighting: Light for Gold, Diamonds and Silver

What kind of light makes diamonds sparkle?

A diamond's sparkle comes from point-source light. Narrow-beam spotlights from a single point are used instead of widely diffused light; crystal or lensed optics increase the sparkle.

Details: Jewellery and Display Lighting: Light for Gold, Diamonds and Silver

What CRI should a jewellery display have?

At least Ra 90 is recommended. A high R9 value, which represents red, is also an advantage for showing stones and gold in their true colours.

Details: Jewellery and Display Lighting: Light for Gold, Diamonds and Silver

Does LED light damage jewellery or products in the display?

LEDs emit much less heat than halogen and metal halide lamps and almost no UV, so they do not heat the product inside the display and reduce heat build-up on the display glass.

Details: Jewellery and Display Lighting: Light for Gold, Diamonds and Silver

Which colour temperature should a hotel room have?

As it is a place to rest, warm white of 2700K–3000K is preferred. At the bathroom mirror, 3000K–4000K high-CRI light that shows the face accurately suits make-up and shaving.

Details: Hotel Lighting: Lighting Design for Lobbies, Rooms, Corridors and Restaurants

Should hotel corridors stay fully lit at night?

No. With motion sensors or time programmes, the light can be dimmed to a low level at night and raised when someone passes; emergency lighting and escape signage must always remain operational.

Details: Hotel Lighting: Lighting Design for Lobbies, Rooms, Corridors and Restaurants

Why is DALI preferred in hotels?

With DALI each luminaire is addressed individually; day, evening and night scenes in the lobby, integration with key-card energy systems in rooms and central fault monitoring become possible.

Details: Hotel Lighting: Lighting Design for Lobbies, Rooms, Corridors and Restaurants

How is a hotel façade lit?

Wallwashers and narrow-beam luminaires that emphasise the architecture are used on the façade, with a brighter area welcoming guests at the entrance. Outdoor luminaires should be at least IP65.

Details: Hotel Lighting: Lighting Design for Lobbies, Rooms, Corridors and Restaurants

How many lux should an indoor car park have?

According to EN 12464-1, the typical target for parking areas and driving lanes is 75 lx. At entry and exit ramps, 300 lx by day (so the eye can adapt from daylight) and 75 lx at night are recommended; 300 lx is targeted at ticket and payment points.

Details: Car Park Lighting: Lux, IP and Sensors in Indoor and Outdoor Car Parks

What IP rating should car park luminaires have?

In indoor car parks at least IP65 is recommended because of dust, humidity and floor washing. In open car parks, pole-mounted luminaires should be IP66–IP67 against rain and dust.

Details: Car Park Lighting: Lux, IP and Sensors in Indoor and Outdoor Car Parks

How much do sensors save in car park lighting?

Most car parks are empty for most of the day. When motion-sensor luminaires dim to 10–30% while nobody is there and go to full power when a vehicle or pedestrian is detected, energy consumption falls clearly compared with a system running at full power all the time; the ratio depends on usage.

Details: Car Park Lighting: Lux, IP and Sensors in Indoor and Outdoor Car Parks

Which colour temperature should a car park use?

Indoor car parks usually use neutral to cool white of 4000K–5000K for alertness and visibility; Ra 80 luminaires are sufficient for distinguishing colours.

Details: Car Park Lighting: Lux, IP and Sensors in Indoor and Outdoor Car Parks

What is the difference between single-phase and three-phase track?

On single-phase track all spotlights are fed from one circuit and switch on and off together. On three-phase track the spotlights can be connected to three separate circuits via their adaptors, so different groups on the same track can be controlled separately.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

Which beam angle should a track spotlight have?

A narrow 12°–20° beam to accent a single product or painting, a medium beam of about 34° for shelves and displays, and a wide 44°–60° beam to light larger areas.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

How many watts should a track spotlight be?

It depends on the ceiling height, target illuminance and beam angle. For window and shelf accents under ceilings of about 3 metres, 20–30 W models are preferred; for high ceilings and wide beams, 30–40 W and above. The exact value is determined by calculation.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

What does a honeycomb louvre on a track spotlight do?

It reduces glare by preventing a direct view of the light source; it is particularly recommended at angles close to the customer's eye level.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

What is the difference between a track spotlight and a recessed downlight?

A track spotlight can be slid along, rotated, added to or removed from a ceiling-mounted track, which suits spaces whose layout changes. A recessed downlight is built into the ceiling and stays in a fixed position, which suits ceilings meant to look plain.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

How large an area does a track spotlight light?

The diameter of the pool of light is about 2 × distance × tan(beam angle ÷ 2). From 3 m away, a 20° spotlight lights a circle of about 1.06 m, a 34° spotlight 1.83 m and a 60° spotlight 3.46 m.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

What is magnetic track?

A slim track system running on 48 V DC low voltage, on which luminaires are held by magnets. The driver sits inside the track or in the ceiling void.

Details: What Is a Track Spotlight and How to Choose One? Beam Angle, Track Type and Wattage

Which mounting types are linear luminaires used in?

Surface-mounted (directly on the ceiling), recessed (into a suspended ceiling) and pendant (on suspension wires). Pendant models can emit light downwards only (direct) or both downwards and onto the ceiling (direct/indirect).

Details: What Is Linear Lighting? Mounting Types, Profiles and Diffuser Choice

What is the difference between opal and micro-prismatic diffusers?

An opal diffuser spreads light softly and evenly and hides the LED dots. A micro-prismatic diffuser directs light in a controlled way and lowers glare (UGR); it suits office areas with screens.

Details: What Is Linear Lighting? Mounting Types, Profiles and Diffuser Choice

Can linear luminaires be joined end to end?

Yes. With systems such as Line-Set, luminaires are joined to create a continuous line of light along a corridor or open-plan office; feed points are planned at the design stage.

Details: What Is Linear Lighting? Mounting Types, Profiles and Diffuser Choice

What are the advantages of direct/indirect pendant linear luminaires?

Because part of the light is reflected from the ceiling, the ceiling does not stay dark, the space looks more open and glare is reduced; they are preferred in open-plan offices and meeting rooms.

Details: What Is Linear Lighting? Mounting Types, Profiles and Diffuser Choice

What is the difference between a downlight and a recessed spotlight?

A downlight is usually wide-beam and fixed, for general lighting. A recessed spotlight can have a narrower beam and is often adjustable; it is used for accent lighting.

Details: How to Choose a Recessed Spotlight? Cut-Out Size, Beam Angle and Layout

How is the cut-out size of a recessed spotlight determined?

The cut-out size is given in each model's datasheet. The ceiling hole is cut to this size; there must be enough depth in the ceiling void for the luminaire body and driver.

Details: How to Choose a Recessed Spotlight? Cut-Out Size, Beam Angle and Layout

What spacing should recessed spotlights have?

As a starting point, a spacing close to the ceiling height is taken (for example, wide-beam downlights at about 1.2–1.5 m intervals under a 2.8 m ceiling); the spacing is verified by calculation according to the beam angle for uniform light.

Details: How to Choose a Recessed Spotlight? Cut-Out Size, Beam Angle and Layout

Which recessed spotlight should be used in a bathroom?

Models with at least IP44 protection; higher protection is preferred close to the shower.

Details: How to Choose a Recessed Spotlight? Cut-Out Size, Beam Angle and Layout

Should concealed lighting use 12 V or 24 V?

24 V is preferred for long runs: it draws a lower current for the same power, so voltage drop is reduced and there is less loss of brightness at the end of the run. 12 V is sufficient for short applications.

Details: How to Install Concealed Lighting? LED Strip, Profiles and 12 V vs 24 V

Why should LED strip be used inside a profile?

An aluminium profile dissipates the strip's heat and extends its life, while the diffuser hides the LED dots and creates an even line of light.

Details: How to Install Concealed Lighting? LED Strip, Profiles and 12 V vs 24 V

How is a driver chosen for LED strip?

Multiply the strip's power per metre by the total length and add a margin of about 20 percent. For example, 10 metres of 14 W/m strip = 140 W; a driver of at least about 170 W is chosen.

Details: How to Install Concealed Lighting? LED Strip, Profiles and 12 V vs 24 V

How much space is needed for a cove light in a suspended ceiling?

Enough distance must be left between the strip and the ceiling for the light to spread across it; very narrow gaps create a sharp, patchy line on the ceiling. The dimension is set in the installation drawings according to the cornice or plasterboard detail.

Details: How to Install Concealed Lighting? LED Strip, Profiles and 12 V vs 24 V

Which colour temperature should be used inside a mosque?

Usually 3000K–4000K; in mosques with historic stone and timber surfaces, warm 2700K–3000K tones show the texture better.

Details: Mosque Lighting: A Guide to the Interior, Dome, Mihrab and Minaret

Can mosque chandeliers be converted to LED?

Yes. The appearance of the existing chandeliers can be retained while converting to LED at lamp-holder and lamp level; the colour temperature and brightness should be the same throughout the chandelier.

Details: Mosque Lighting: A Guide to the Interior, Dome, Mihrab and Minaret

How is a mosque dome lit?

With linear or narrow-beam luminaires concealed at the base of the dome, showing the painted decoration evenly and without glare; the light sources are hidden from the congregation's view.

Details: Mosque Lighting: A Guide to the Interior, Dome, Mihrab and Minaret

Why are lighting scenes important in a mosque?

Daily prayers, Friday prayers, Eid, Tarawih and cleaning need different light levels; scenes save energy and make the attendant's work easier.

Details: Mosque Lighting: A Guide to the Interior, Dome, Mihrab and Minaret

What does a lighting consultant do?

Analyses the requirements, sets target values according to the standards, carries out the illuminance calculation, selects luminaires and the control system, prepares energy and cost comparisons and supervises the installation.

Details: What Is Lighting Consultancy and When Is It Needed?

Is consultancy needed when converting existing lighting to LED?

It is recommended. Replacing old luminaires one-for-one with the same number of LED luminaires often gives either more light and energy than necessary or uneven illuminance. With measurement and calculation, a better result can be achieved with fewer luminaires.

Details: What Is Lighting Consultancy and When Is It Needed?

What is delivered at the end of the consultancy?

A calculation report for each area, a luminaire layout plan, a luminaire list and technical specification, a summary of installed power and energy consumption and, where needed, control scenes.

Details: What Is Lighting Consultancy and When Is It Needed?

How many lux should a shop have?

The typical target for general lighting in the sales area is 300 lux, with 500 lux at the checkout. Accented products and shelves are given 3 to 5 times this value.

Details: How to Light a Shop? Lighting Decisions That Affect Sales

Which luminaires are used in retail lighting?

Recessed downlights or linear luminaires for general lighting, adjustable track spotlights for product and shelf accents, narrow-beam spotlights in the window and concealed LED strip inside shelves.

Details: How to Light a Shop? Lighting Decisions That Affect Sales

Which colour temperature should a clothing store choose?

Usually 3000K–3500K, a warm tone that does not distort product colours. CRI 90 or higher is essential for products to look right.

Details: How to Light a Shop? Lighting Decisions That Affect Sales

How many lux should an office have?

An average of 500 lux is targeted at desks. Typical values are 750 lux for fine work such as technical drawing, 200 lux in archives and 100 lux in corridors.

Details: Lux Levels in Office Lighting: A Guide Based on EN 12464-1

What does UGR 19 mean?

UGR (Unified Glare Rating) is the degree of glare from luminaires; the lower the value, the less glare. For screen work in offices the upper limit is 19.

Details: Lux Levels in Office Lighting: A Guide Based on EN 12464-1

Which colour temperature suits an office?

Usually 4000K neutral white; it supports concentration and shows colours naturally. 3000K can be preferred in break areas.

Details: Lux Levels in Office Lighting: A Guide Based on EN 12464-1

How can office lighting energy be reduced?

High-efficacy (lm/W) luminaires, daylight sensors near windows, presence sensors in meeting rooms and toilets, and dimming via DALI are the most effective methods.

Details: Lux Levels in Office Lighting: A Guide Based on EN 12464-1

How many lux should a factory have?

It depends on the precision of the work: about 300 lux for rough assembly, 500 lux for medium, 750 lux for fine assembly and 1000 lux for precision work. 100 lux is typical in warehouses and storage areas.

Details: Factory and Warehouse Lighting: Lux Levels, Luminaires and IP Ratings

Which IP rating should be chosen for factory lighting?

IP20–IP40 may be enough in dry, clean production areas; IP65 is recommended in dusty environments and IP66–IP67 in areas with pressure washing.

Details: Factory and Warehouse Lighting: Lux Levels, Luminaires and IP Ratings

Which luminaire is used in a high-ceiling warehouse?

High-flux industrial luminaires with narrow or medium light distribution; in racking aisles, models with a long, narrow distribution that spreads light along the aisle are preferred.

Details: Factory and Warehouse Lighting: Lux Levels, Luminaires and IP Ratings

What contrast ratio should accent lighting have?

If the accented object receives 3 times more light than its surroundings (3:1), the accent is noticeable; 5 times (5:1) gives a strong focus and 10 times or more (10:1) a dramatic effect. If the surroundings are at 100 lux, 500 lux on the object is targeted for a 5:1 accent.

Details: What Is Accent Lighting and How Is It Applied in Spaces?

Which luminaires are used for accent lighting?

Track spotlights in shops and exhibitions that need flexibility, adjustable recessed spotlights in minimal ceilings, wallwashers on textured walls, and miniature spotlights with 8°–12° beams for small objects such as jewellery displays.

Details: What Is Accent Lighting and How Is It Applied in Spaces?

Which beam angle should be chosen for accent lighting?

8°–15° for small objects, about 24° for medium-sized surfaces such as paintings and shelves, and 36° or more for larger areas.

Details: What Is Accent Lighting and How Is It Applied in Spaces?

What CRI should accent lighting have?

CRI 90 or higher is required for objects where colour matters, such as artworks, textiles and food. If red tones are important, an R9 value of at least 50 should also be written into the specification.

Details: What Is Accent Lighting and How Is It Applied in Spaces?

How many luminaires can be connected to a DALI line?

A DALI line supports 64 addresses; each luminaire can be controlled individually or in groups, and up to 16 scenes can be stored in each luminaire. Larger projects use several lines and gateways.

Details: DALI, KNX and 1-10V: Lighting Control Systems

What is the main difference between DALI and 1-10V?

1-10V is a one-way analogue signal; all luminaires on the line dim to the same level and no fault information is returned. DALI is digital and two-way; each luminaire is addressed separately, and information such as operating hours and driver faults can be monitored centrally.

Details: DALI, KNX and 1-10V: Lighting Control Systems

Can KNX and DALI be used together?

Yes. The most common architecture is a hybrid in which KNX manages all building systems and DALI controls the luminaires precisely. The two systems are connected with KNX-DALI gateways.

Details: DALI, KNX and 1-10V: Lighting Control Systems

Does polarity matter in DALI wiring?

No. A DALI line can be laid in star, branch or mixed topology without regard to polarity; two extra cores added to the supply cable are usually enough.

Details: DALI, KNX and 1-10V: Lighting Control Systems

What should I look for when choosing an indoor luminaire?

Luminous flux (lumen) and efficacy (lm/W), colour temperature, CRI (80 in offices, 90 and above in shops), beam angle, glare in offices (UGR below 19) and compatibility with the dimming system (1-10V, DALI, Triac) should be assessed together.

Details: Indoor Lighting

Which luminaire is suitable for office lighting?

Low-glare (UGR < 19) linear, recessed or surface-mounted luminaires, 4000K colour temperature and at least CRI 80 are recommended. According to EN 12464-1, 500 lux is targeted in work areas used for writing and reading.

Details: Indoor Lighting

Which luminaire is used in damp indoor areas such as bathrooms?

Luminaires with at least IP44 protection should be chosen for damp areas. Check the IP rating on the product pages.

Details: Indoor Lighting

What is the difference between recessed and surface-mounted spotlights?

A recessed spotlight is built into the suspended ceiling and sits flush with it. A surface-mounted spotlight is mounted directly on surfaces without a ceiling void.

Details: Recessed Downlights & Spotlights

How is the ceiling cut-out determined for a recessed spotlight?

Each product page gives the cut-out diameter; the ceiling hole is cut to this size. Also check that there is enough depth in the ceiling for the luminaire and driver.

Details: Recessed Downlights & Spotlights

Can recessed spotlights be used in bathrooms?

Yes, models with IP44 or higher can be used in damp areas such as bathrooms.

Details: Recessed Downlights & Spotlights

When is a surface-mounted luminaire preferred?

When there is no suspended ceiling, the ceiling void is insufficient, or the luminaire is meant to be a visible design element.

Details: Surface-Mounted Downlights

Are there pendant versions of the surface-mounted models?

Yes. Flu 90-85, Madame 85-150 and Pollux 60-100 are also available as pendant versions with the same housing.

Details: Surface-Mounted Downlights

How high above the table should a pendant be hung?

Above dining and meeting tables the luminaire is usually positioned 70–90 cm above the table surface, so the light is focused on the table without dazzling the people seated.

Details: Pendant Luminaires

Can the suspension length of a pendant be adjusted?

Pendant models are mounted with suspension wires; the length is adjusted to the ceiling height during installation.

Details: Pendant Luminaires

Which track does a track spotlight fit?

The spotlight adapter must be compatible with the track system (single-phase or three-phase). Tell us your track type and we will quote with the right adapter.

Details: Track Spotlights

Which beam angle should I choose for a track spotlight?

A narrow beam (about 15°–24°) to accent a single product or display, a wide beam (36° and above) to light shelves and larger areas.

Details: Track Spotlights

What CRI should a track spotlight have in a shop?

CRI 90 and above is recommended so that product colours look right; for textiles and food also ask for the R9 value.

Details: Track Spotlights

What is the difference between a linear luminaire and an LED panel?

An LED panel emits light from a square or rectangular surface. A linear luminaire forms a slim, long line; it can follow architectural lines and be joined end to end to form continuous lines of light.

Details: Linear Luminaires

What should I consider when using linear luminaires in offices?

In work areas with screens, choose models with low-glare diffusers and a glare rating (UGR) below 19.

Details: Linear Luminaires

How do I choose between Line S, Line S Optio and Line L?

Line S, with its slim body and opal diffuser, gives a clean line of light; Line S Optio, with lens optics, suits directing and accenting light; Line L, with its wide opal diffuser, suits soft, even general lighting. Length and quantity are determined from the target illuminance with a DIALux calculation.

Details: Line Series

Can Line luminaires be joined together?

For projects that need a continuous line of light, the Line-Set system is used.

Details: Line Series

How long can a Line-Set line be?

Line length is planned per project; total power and feed points are calculated at the design stage.

Details: Line-Set Profile System

Can a Line-Set line turn corners?

For projects requiring corners and special shapes, the decorative linear series (such as L-Line, Cross Line and Quadra Line) can be considered.

Details: Line-Set Profile System

Are decorative linear luminaires sufficient for general lighting?

Yes, with the right wattage and layout they provide general lighting. The wattage and luminous flux options of each model are in the datasheet on the product page.

Details: Decorative Linear Luminaires

What size options are available for decorative luminaires?

The size and wattage options of each model are on the product page and in its datasheet. Contact us for custom sizes for your project.

Details: Decorative Linear Luminaires

Should I choose a 12 V or a 24 V LED strip?

24 V is preferred for long runs: it draws less current for the same power, so voltage drop is lower and there is less loss of brightness at the end of the run. 12 V is sufficient for short applications.

Details: Concealed (Cove) Lighting Profiles

Should the LED strip be used with an aluminium profile?

Yes, this is recommended. The aluminium profile dissipates the heat of the strip, extending its life, and its diffuser removes visible dots for an even line of light.

Details: Concealed (Cove) Lighting Profiles

Which colour temperature should be used in factory lighting?

In production areas requiring attention and precision, 4000K–5000K neutral to cool white light supports operator alertness.

Details: Industrial High-Bay Luminaires

Why is the IP rating important for industrial luminaires?

If the internal components are not protected in areas with dust, humidity and washing, lifetime is reduced. Choose IP65 and above in such areas and IP66–IP67 where washing takes place.

Details: Industrial High-Bay Luminaires

How many luminaires does a factory need?

The required illuminance depends on the precision of the work; the number and layout of luminaires are calculated with DIALux based on ceiling height and the layout plan.

Details: Industrial High-Bay Luminaires

How does a magnetic track system work?

The track is powered by an external 48 V DC driver; the modules hold onto the track with magnets and take their power from it. Modules are positioned by sliding them along the track.

Details: 48 V Magnetic Track Lighting

Can magnetic track luminaires be dimmed?

The Lyra series offers on/off, DALI and Tuya wireless (Wi-Fi / Bluetooth) control; smart CCT models also allow the colour temperature to be adjusted.

Details: 48 V Magnetic Track Lighting

Which driver is used for magnetic track?

An external 48 V DC magnetic track driver rated for the total load on the track is used; it is selected at the design stage according to the total wattage.

Details: 48 V Magnetic Track Lighting

What is the difference between single-phase, three-phase and DALI track?

Single-phase track carries one circuit, so all spotlights on it switch together. Three-phase track carries three separate circuits; spotlights are wired to different circuits and switched zone by zone. DALI track adds a DALI control line to the three circuits, so DALI-driven spotlights are dimmed individually.

Details: Track Systems

Can magnetic track and three-phase track be interchanged?

No. Magnetic track runs on 48 V DC and luminaires are held by magnets; three-phase track runs on mains voltage and luminaires fit via a track adapter. The track, connectors and luminaires of each system only work within that system.

Details: Track Systems

Which parts does a track system need?

Each run needs track lengths, a power feed at the supply end, an end cap at the other end, straight/L/T/X connectors to join tracks, and for suspended mounting, suspension brackets and wires. Send us your track layout and we will prepare the parts list.

Details: Track Systems

When is single-phase track chosen?

Where all spotlights on the track switch together and no separate circuits are needed: small shops, homes, offices and meeting rooms. For zone-by-zone control, choose three-phase track.

Details: Single-Phase Track and Accessories

What is the driver adapter for?

It connects driverless LED luminaires directly to single-phase track; a 30 W, 700 mA driver is built into the adapter and other currents are available on request.

Details: Single-Phase Track and Accessories

How is the circuit selected on three-phase track?

The circuit feeding each spotlight is selected on its track adapter, so spotlights on the same track are controlled by three separate switches or dimmers.

Details: Three-Phase Track and Accessories

How is recessed three-phase track installed?

A slot is cut in the plasterboard ceiling; the track is screwed to the ceiling with recessed mounting clips fitted to its back, leaving the 56 mm flanges flush with the ceiling. Standard three-phase connectors are used at corners and joints.

Details: Three-Phase Track and Accessories

Which luminaires does DALI track need?

Track spotlights with DALI drivers and DALI track adapters. Luminaires are addressed over the DALI line; dimming and scenes are managed from the DALI controller.

Details: DALI Track and Accessories

Can three-phase connectors be used on DALI track?

No. DALI connectors carry the DALI line along with the power circuits; standard three-phase connectors do not.

Details: DALI Track and Accessories

What is the difference between trimless and spring-clip recessed magnetic track?

Trimless track is installed before the plasterboard is finished; its wings disappear under the plaster to leave a frameless line. Spring-clip track is held by springs in a slot cut into a finished ceiling, leaving a slim 8 mm trim.

Details: 48 V Magnetic Track and Accessories

Where does the magnetic track driver go?

In-track drivers sit inside the track and need no separate box; 50, 100, 200 and 300 W versions are available. The remote driver (200 and 300 W) goes in the ceiling void or a panel and connects to the track via the power feed.

Details: 48 V Magnetic Track and Accessories

How does magnetic track turn a corner?

With the L corner or vertical L corner for the track type; a flexible connector inside the corner carries power from one track to the next.

Details: 48 V Magnetic Track and Accessories

How is a facade lit with a wallwasher?

The wallwasher is mounted at the foot of the wall or close to the facade; a narrow beam (10°) grazes the wall to bring out texture, while a wide beam (40°–60°) washes the surface more evenly.

Details: Facade & Wallwasher Luminaires

What IP rating should a facade luminaire have?

As it is directly exposed to rain and dust, at least IP65, preferably IP66, should be chosen.

Details: Facade & Wallwasher Luminaires

How does rope lighting work?

48 V DC conductors run inside the flexible rope. The rope is fed from a ceiling junction box or driver box and fixed to the wall with a tensioner; luminaires clip onto the rope and slide to any point along it.

Details: Rope Lighting

How many luminaires can one driver supply?

The system uses a 150 W, 48 V DC driver. The total power of the luminaires on the rope must not exceed the driver rating; for example, up to 10 luminaires of 15 W can be connected to one driver. Longer runs get a second driver.

Details: Rope Lighting

Where is rope lighting suitable?

It suits interiors where luminaires are to be strung along a free line: restaurant and café tables, hotel lobbies, atriums, shop windows and high-ceilinged living rooms. As the system is IP20, it is for dry indoor spaces only.

Details: Rope Lighting

How is a spike-mounted garden luminaire installed?

The spike is driven into the ground; the cable is connected with an outdoor-rated joint and protective box.

Details: Garden & Landscape Lighting

Which lamp is used in a garden luminaire?

The Luna series uses an E27 LED lamp; colour temperature and power depend on the chosen lamp.

Details: Garden & Landscape Lighting

Which ceilings do LED panels fit?

They sit in mineral-fibre (60×60 grid) suspended ceilings, and clip-in versions fit metal clip-in ceilings. Where there is no suspended ceiling, a surface-mounting frame can be used.

Details: LED Panels

How many watts should a 60×60 LED panel be?

36 W is common for 60×60 panels in offices; the right wattage and quantity are calculated from the target illuminance (e.g. 500 lux at the desk) and ceiling height.

Details: LED Panels

Which panel should be chosen for hospitals?

Laboratories and clean rooms call for IP65 sealed panels with a glass front that keep out dust and moisture. Requirements for special areas such as operating theatres are set by the project specification.

Details: LED Panels

At what height are high-bay luminaires used?

Usually on ceilings of 6 metres and above; on lower ceilings, wide-distribution linear or vapour-proof luminaires are more suitable.

Details: High-Bay Luminaires

How many watts does a warehouse high-bay need?

It is calculated from ceiling height, rack layout and target illuminance (about 100 lux in storage, 300 lux in dispatch); wattage and quantity are set with DIALux.

Details: High-Bay Luminaires

Linear or round (UFO) high-bay?

Linear luminaires that spread light along the aisle suit racking aisles, while models with wide, even distribution suit open production areas.

Details: High-Bay Luminaires

What is a vapour-proof luminaire?

A vapour-proof (sealed) luminaire is protected against dust and water, usually to IP65.

Details: Vapour-Proof Luminaires

Which vapour-proof luminaire suits a car park?

Enclosed car parks commonly use 1200–1500 mm, 36–60 W IP65 vapour-proof luminaires; versions with motion sensors dim when the area is empty to save energy.

Details: Vapour-Proof Luminaires

Polycarbonate or aluminium body?

A polycarbonate body is light and corrosion-resistant; an aluminium body dissipates heat better and is more impact-resistant. The choice depends on the environment.

Details: Vapour-Proof Luminaires

What IP and IK rating should an in-ground luminaire have?

At least IP67 is recommended where water can collect, and IK10 impact resistance in areas with pedestrian traffic.

Details: In-Ground Luminaires

How is an in-ground luminaire installed?

The installation box is first set into the ground, the cable is connected with an underwater joint, then the luminaire is placed in the box and fixed with its flange.

Details: In-Ground Luminaires

Outdoor lighting

What is the difference between architectural lighting and general lighting?

General lighting provides the even light that makes seeing and working possible. Architectural lighting brings out walls, ceilings, façades and textures to define the form and atmosphere of a space.

Details: What Is Architectural Lighting? Techniques Indoors and Outdoors

What is the difference between wallwashing and grazing?

In wallwashing the luminaire is set back from the wall and the surface is lit evenly, which suits flat, painted surfaces. In grazing the luminaire sits at the foot of the wall and the light skims the surface, revealing the texture of stone or brick through shadows.

Details: What Is Architectural Lighting? Techniques Indoors and Outdoors

Which colour temperature should be used for façade lighting?

On stone and historic buildings 2700K–3000K warm white enriches the material; on glass, metal and concrete 4000K may suit better. The colour temperature is chosen by testing on a material sample.

Details: What Is Architectural Lighting? Techniques Indoors and Outdoors

Does architectural lighting cause light pollution?

If applied badly, yes. Narrow, controlled optics that send light only to the target surface, positioning that limits light spill to the sky, and scenes that dim after midnight reduce light pollution.

Details: What Is Architectural Lighting? Techniques Indoors and Outdoors

At which stage of a project should architectural lighting be planned?

Before ceiling and wall details are finalised. Concealed light niches, recess depths, wall distances and electrical infrastructure depend on lighting decisions, and changing them later increases cost.

Details: What Is Architectural Lighting? Techniques Indoors and Outdoors

Which technique is used most in façade lighting?

Uniform wallwashing on flat, large surfaces, grazing light on textured surfaces such as stone and brick, and narrow-beam accents on elements such as columns and domes.

Details: How to Light a Façade? Techniques, Luminaires and Design

Which colour temperature should be chosen for façade lighting?

Warm 2700K–3000K tones for stone, brick and historic fabric; 4000K can be preferred for modern façades dominated by glass and metal. Coloured (RGB) effects are planned as scenes for special occasions.

Details: How to Light a Façade? Techniques, Luminaires and Design

Where are façade luminaires mounted?

As in-ground or wall-base luminaires at the foot of the surface, linear luminaires under the eaves, or floodlights on an opposite building or pole; the choice depends on the angle of incidence of the light and the texture of the façade.

Details: How to Light a Façade? Techniques, Luminaires and Design

How is light pollution prevented in façade lighting?

Asymmetric optics direct the light only onto the surface, anti-glare accessories are added to the luminaires, and programmed dimming or switching off is applied late at night.

Details: How to Light a Façade? Techniques, Luminaires and Design

How far from the wall should a wallwasher be placed?

As a general starting value, at about one third of the wall height; the exact distance and luminaire spacing are determined by calculation according to the luminaire's light distribution.

Details: What Is a Wallwasher? Wallwashing Lighting and Choosing Luminaires

Are wallwashers used indoors?

Yes. Lighting the walls in lobbies, galleries, shops and meeting rooms makes the space look more open; outdoors they are used for façade lighting.

Details: What Is a Wallwasher? Wallwashing Lighting and Choosing Luminaires

What IP rating should a wallwasher have?

IP20 may be enough indoors; on exterior façades at least IP65, and IP67 for in-ground models.

Details: What Is a Wallwasher? Wallwashing Lighting and Choosing Luminaires

What does wallwasher mean?

A wallwasher is a luminaire with an asymmetric optic that "washes" a wall with light, spreading it evenly from top to bottom.

Details: What Is a Wallwasher? Wallwashing Lighting and Choosing Luminaires

How far apart should wallwashers be spaced?

As a starting point, the spacing between luminaires is 1 to 1.3 times their distance from the wall. For a 3 m high wall that is about 1.0–1.3 m; the exact value is calculated from the luminaire's photometric data.

Details: What Is a Wallwasher? Wallwashing Lighting and Choosing Luminaires

What is the minimum IP rating for outdoor luminaires?

At least IP65 is recommended for standard outdoor applications exposed to rain. IP67 should be chosen for in-ground installations or places where water can collect.

Details: Outdoor Lighting

What is Astrodim?

Astrodim means the LED driver automatically dims the light at pre-programmed times during the night. Power is reduced after midnight when traffic decreases, saving energy without an extra control cable.

Details: Outdoor Lighting

What should an outdoor luminaire housing be like?

An aluminium housing, electrostatic powder coating against corrosion and a UV-resistant optical lens are basic requirements for a long life outdoors.

Details: Outdoor Lighting

How far apart should bollards be placed?

Spacing depends on the light distribution of the bollard and the required illuminance of the path; we recommend calculating it at the design stage for an even light level.

Details: Bollards

What IP rating should a bollard have?

Because it is exposed to rain and dust, at least IP65 is recommended; IP67 should be preferred where ground water can collect.

Details: Bollards

Which standard is road lighting calculated to?

Road lighting is calculated to EN 13201, taking into account the road class, traffic density and width; pole spacing and luminaire wattage are determined by this calculation.

Details: Street & Area Lighting

How much does Astrodim save?

Savings depend on the hours and the level of dimming during the night. Reducing power when traffic decreases lowers energy consumption without additional wiring.

Details: Street & Area Lighting

Which Zapata model should I choose?

Zapata, Zapata T, Zapata Y and Zapata X are available in different wattage ranges; lower wattages suit narrow site roads and higher wattages wide roads. The wattage and lumen values of each model are in its datasheet.

Details: Street & Area Lighting

Emergency lighting

How long should emergency lighting stay on?

At least 1 hour for escape lighting; for hospitals, large factories and buildings with long evacuation times the regulation or project specification usually requires 3 hours.

Details: How Should Emergency Lighting Be Maintained? Standards and Practical Guide

When should an emergency lighting battery be replaced?

The most reliable sign is that the battery cannot complete the required duration in the annual full-discharge test. Typical lifetimes are 4–6 years for NiCd, 3–5 years for NiMH and 8–10 years or more for LiFePO4 batteries.

Details: How Should Emergency Lighting Be Maintained? Standards and Practical Guide

Should emergency lighting test results be recorded?

Yes. Every test and battery replacement should be entered in the logbook; buildings without records may face sanctions during inspections. Systems with automatic test modules keep this record themselves.

Details: How Should Emergency Lighting Be Maintained? Standards and Practical Guide

How long should emergency lighting operate?

At least 1 hour for escape lighting; 3 hours where the regulation or project specification requires it (e.g. hospitals, large facilities).

Details: Emergency Lighting

What is the difference between an emergency kit and an emergency luminaire?

An emergency kit is a module installed in an existing LED luminaire that keeps it lit from a battery during a power failure. An emergency luminaire is a separate luminaire that operates independently with its own battery.

Details: Emergency Lighting

How often should emergency lighting be tested?

A short functional test, a monthly test and an annual full-discharge test measuring the real battery capacity should be carried out, and the results recorded in the logbook.

Details: Emergency Lighting

Which luminaires can an emergency kit be fitted to?

The output power and voltage range of the kit must match the LED load of the luminaire. Choose the model according to the LED voltage of the luminaire and the required emergency duration; if in doubt, ask our technical team.

Details: Emergency Conversion Kits

How long does a luminaire stay lit with an emergency kit?

Duration depends on the battery capacity of the kit and the power it delivers in emergency mode. At least 1 hour is targeted for evacuation, and 3 hours where the regulation or specification requires it.

Details: Emergency Conversion Kits

When should the battery of an emergency kit be replaced?

A battery that cannot complete the required duration in the annual full-discharge test should be replaced. Battery life depends on its chemistry; LiFePO4 batteries last longer than NiCd and NiMH batteries.

Details: Emergency Conversion Kits

What is the difference between maintained and non-maintained emergency luminaires?

A maintained luminaire is also lit in normal operation and continues on battery during a power failure. A non-maintained luminaire only switches on when the mains fails.

Details: Emergency Luminaires

How quickly should an emergency luminaire switch on?

It should switch on within a few seconds of a mains failure; at least 1 lux must be provided on the centre line of escape routes.

Details: Emergency Luminaires

Where are exit signs installed?

Above emergency exit doors, at corridor turns, at the top of stairs and at intervals that ensure at least one sign is visible from every point of the escape route.

Details: Exit Signs

Should exit signs be maintained?

Exit signs are usually operated in maintained mode so that the escape route can be read at any time.

Details: Exit Signs

How do I choose a spare battery?

Choose a battery with the same type, voltage and capacity as the battery of the existing kit or luminaire. If in doubt, send us the kit model.

Details: Batteries & Accessories

When does a battery need replacing?

If the emergency lighting cannot complete the required duration in the annual full-discharge test, the battery should be replaced.

Details: Batteries & Accessories